Contact us
   
 
Our Products
 
VET Patient Monitor

 

Contec VET 5 Para Patient Monitor CMS 8000

 

 
Accessories

 

ECG Connectors & Cables For All Types Of Machines

 

SpO2 Connectors & Probes for All Brands Of Machines

 

NIBP Cuffs- Reusable - Adult, Pediatric , Neonatal

 

ECG & Fetal Monitor Paper Rolls for All Brands of Machines

 

NIBP Cuffs- Disposable- Adult, Pediatric , Neonatal

 

SpO2 Probe - Disposable

 

ECG Clamps and Bulbs - Adult & Pediatric

 

Disposable ECG Electrodes

 

ECG Jel

 

Ultrasound Jel

 

ECG / Ultrasound Jar

 

Admin

 

 

 

 
Knowledge Base
 
Specification

 

Warranty

 

Service & Support

 

 

VET Patient Monitor

Contec VET 5 Para Patient Monitor CMS 8000

 


 

*12.1” Colour TFT LCD display with waveforms upto 8 Channels

*Standard Parameters:ECG ,NIBP,SpO2,Respiration,Temperature,Pulse Rate

*Upgrades:IBP, ETCO2,Network,Printer

*Graphic and tabular Trend for 96 hours for all parameters

*Multi Screen format

*Audible and Visual alarms with adjustable alarm ranges

*Power data management and storage capacity

*Manual or Automatic NIBP measuring with 500 unit memory

*Rechargeble Lead Acid Cell /AC Mains

*Weight: 4.5Kg

 

ECG:

*Heart Rate Range :10~300 bpm

*Accuracy : +/-1% or +/-1 bpm ,whichever is greater

*Diagnostic: 0.05-75 Hz

*Lead Selection: I,II,III,avR,avF,V1-V6

*S-T Segment Monitoring

*Arrhythmia Analysis: Yes

*Sweep Speed: 12.5mm/s ,25mm/s ,50mm/s

*Gain Selection: : *0.5, *1 ,*2, Auto

 

NIBP:

*Method: Oscillometric

*Measurement Types : Manual, Diastolic, Mean, Pulse Rate

*Operation Mode: Manual, Automatic, STAT

*Measurement Unit: mmHg/kPa selectable Automatic Measurement time : 1-240 min

*Measurement Range:

*Adult/Children   Systolic    25-265 mmHg         Systolic      25-135 mmHg

                             Mean        18-245 mmHg         Mean          18-120 mmHg

                             Diastolic   12-220mmHg          Diastolic     12-110 mmHg

*Cuff Pressure Range :0-300 mmHg

*Alarm:  Optional Alarm range , Alarm events recallable

 

SpO2:

*Display : The Pulse Oxygen Saturation Pulse Intensity ;Plethysmograph wave ;Pulse  

  Rate

*Measurement Range: 0~100 %                  *Resolution: 1%

*Accuracy: +/-2% or +/-1 bpm ,whichever is greater

*Pulse Rate Measurement Range: 25~250 bpm

*Pulse Rate Accuracy: +/-2 bpm

*Alarm: Optional Alarm range , Alarm events recallable

 

Temperature:

*Effective Measurement Range :0-50 Degrees C

*Resolution: 0.10 Degree C                      *Accuracy: +/-0.1 Degree C

* Average Response Time : <2 min

 

Respiration:

*Method :RA-LL Impedance                  *Measurement Range: 0~120 bpm

 
 

 